Product Introduction
- Functions and technical indicators
1.1 Simulation module technical specifications
a) 4-channel synchronization/resolver signal simulation channels, 4-channel synchronization/resolver signal programmable switching;
b) Reference voltage: 2.0 Vrms ~ 115Vrms programmable;
c) Signal voltage: 1.0V~90V programmable
d) Frequency: 47Hz~20000Hz;
e) Angle range: 0°~359.999° continuous change;
f) Output driving capability: 2.2VA, ≥11.8V; 200mArms, <11.8V;
g) Resolution: 0.001°;
h) Dual-channel programmable multi-speed ratio: 2~255, increment is 1;
i) Angle simulation accuracy index:
j) Electrical isolation: ≥500V;
k) With over-voltage protection and over-temperature protection functions;
l) Dynamic simulation function: range ±10000°/sec, resolution 0.01°/sec.
1.2 Measurement module technical specifications
a) 4 channels of synchronous/resolved signal measurement channels, 4 channels of synchronous/resolved signals can be switched programmably;
b) Reference voltage: 2.0Vrms~130Vrms;
c) Signal voltage: 1.0V~90V (resolver), 11.8V~90V (synchronous);
d) Frequency: 47Hz~20000Hz;
e) Angle range: 0°~359.9999°;
f) Angle measurement accuracy index:
g) Angular resolution: 0.0002°;
h) Dynamic measurement range: ±10000°/sec
i) Dual-channel programmable multi-speed ratio: 2~255, increment is 1;
j) Electrical isolation: ≥500V.
1.3 Reference power output
a) One reference power output;
b) Output range: 2 Vrms~115Vrms, programmable;
c) Resolution: 0.1V;
d) Output accuracy: ±3% (±6%@>7.5 kHz);
e) Output drive capability: 2.2VA;
f) Output frequency range: 47Hz~10kHz;
g) Output frequency step: 0.1Hz;
h) Output frequency accuracy: 0.1%.
1.4 Other requirements
1.4.1 Power supply requirements: DC5V and DC ± 12V, power consumption not greater than 35W.
1.4.2 Dimensions: 34923430, weight: 1.5kg
1.4.3 Bus structure: VXI